Technical specifications
Range/stroke
Upon customer request
Load capacity
500 kg to 5000 kg
Accuracy
10 µm*
Repeatability
1 µm*
Motion speed
0.8 mm/s*
Parasitic Motion (Pitch and Roll)
1.5 µrad/mm*
Linear encoder
Optional
*The values were obtained by motion tests at 50 mm range with 500 kg load in Open Loop operation, meaning that the motor’s position is commanded to move and stop at the nominal target positions without any feedback from a position sensor. By conducting the test in Open Loop, stepper motor failures, which most likely go undetected in closed-loop operation, are easily identified.